FACILITY REQUIREMENTS • Computer • System Software • S&A 250B or 250C Network Analyzer • Direct Drive Roughing Pump • Cryo, Diffusion or Turbo Pump SYSTEM CONFIGURATION • Power: 220 or 380 Volts, 3-Phase, 15 Amps • Inlet Pressures: 150 PSIG Maximum • Air: 90 PSIG • Nitrogen: 20 PSIG • Water Cooling (Diffusion): 0.15 GPM @ 60 - 80 Deg. F (16-27 Deg. C) • Dimensions: 22 x 70 x 40 inches (54.6 x 177.8 x 101.6 cm) 6300344-01 SCREEN FORMAT
SPECIFICATIONS S&A W-5250S
PLATING SYSTEM • Quartz crystal final frequency adjust plating system • Vertical evaporation and pulse width modulation of
filament power results in minimal plating material usage • Single aperture with three axis adjustment for simple
plating spot alignment • Precision plating to load resonant frequency
using "Measured FL" method • No physical capacitor required • Over 40 different crystal parameter measurements, including DLD and Spurious • S&A 2296 Heater Kit for plating at crystal
turning point temperature 250B Frequency Range: 0.5 MHz - 200 MHz 250C Frequency Range: 0.5 MHz - 500 MHz Plating Performan
ce: ± 1 ppm typical final frequency
± .1 ppm with S&A 2296 Heater Kit Option Throughput: 500 units/hour (100 Position Wheel)
400 units/hour (50 Position Wheel) • Proprietary magnetic wheel uses no sockets • Contacts directly to crystal leads • Standard wheel holds 50 devices and
accepts HC-45 and HC-49 type packages • 100 Position HC-49US wheel available • Various HC-family, SMD and custom
wheels available