Oscillator Sample Reports
 MEASUREMENTS    Supply Current    Logic High Level    Logic Low Level    Short Test    Open Test    Period    Peak to Peak Voltage    RMS Voltage    Linearity    TTL I/O card    Oscilloscope    GPIB Card    System Software    Chassis (optional)    Printer (optional)    Start-up Time    Rise Time    Fall Time    Start Frequency    Frequency    Frequency Min.    Frequency Max.    Duty Cycle    Computer  (minimum Pentium III, 4 PCI slots)    Bench Top Fixture    Frequency Counter Card    Voltmeter / Power Supply Card  (requires full size PCI slot)  SYSTEM CONFIGURATION  SAUNDERS & ASSOCIATES, INC.  6300234-03  SAMPLE REPORTS    High Pull    Low Pull    Total Pull    Power    Tri-State    Bin    Date    Time
Specifications
Saunders
W-280A OSCILLATOR ANALYZER
OSCILLATOR ANALYZER Screen
 Oscillator Frequency Range:  1 KHz - 400 MHz  Oscilloscope Analog Bandwidth:         500 MHz (rise time 1% error at 5  nsec)  S&A  W-280A OSCILLATOR ANALYZER  SPECIFICATIONS    Data can be exported to Microsoft
ExcelTM for custom data analysis
   Load circuitry easily changed via
drop-in module
   Custom printouts can be created
using Crystal ReportsTM(optional)
   Comprehensive oscillator waveform analysis    Selectable test parameters with
user defined QC limits
   User friendly Windows System software    All data is published in Microsoft AccessTM
compatible data base in real time
   Bench top fixture accepts 4-pin
(full or half-pack) device packages
and SMD test sockets
   Measures (5V & 3.3V) PECL, ECL,
TTL, and HCMOS devices with
square wave and sine wave outputs
  Roditi   About Contacts Stock Email Home