5500B
5500B
5500B
5500B
   System Software    Closed Loop Water Cooled
Filament
   Bar Code Reader (Optional)    Printer (Optional)    Quartz Crystal Plating (Optional)  6300108-09  MEASUREMENTS    Resonator 1    Resistance    Inductance    Capacitance    Resonator 2    Resistance    Inductance    Capacitance    Center Frequency    Symmetry    Short Circuit Bandwidth    Resonator Frequency Port 1    Resonator Frequency Port 2    Total Resistance  SYSTEM CONFIGURATION    Vector Voltmeter    Dual Output Synthesizers    X-Y Table Vacuum Assembly    Turbo or Cryo Pump    Direct Drive Roughing Pump    Computer    Light Pole  SAUNDERS & ASSOCIATES, INC.  FACILITY REQUIREMENTS    Power:  220 Volts @ 30 A or 380 Volts @ 20 A, 3-Phase    Inlet Pressures:  150 PSIG Maximum    Air:  90 PSIG    Nitrogen:  20 PSIG (Turbo), 70 PSIG (cryo)    Cryo Water Cooling:  0.5 GPM @70 ° F, typical    Dimensions:  52.5 x 34.5 x 55 Inches (excluding light pole & cryo   compressor) (133.4 x 87.6 x 139.7cm)
Cryo pump compressor 19.5 x 24 x 19 inches
(49.2 x 61 x 48.3 cm) Light pole 39.5 inches (100.3 cm)
5500B
5500B
Component Tray
5500B MCF Plating System
 S&A          5500B MCF
PLATING SYSTEM
   Monolithic Crystal Filter final
frequency adjust plating system
   Plates FE1, FE2 and bandwidth to
user specified targets
   Measured parameters are checked  against easy to define Q.C. limits after
each filter is plated
   Measurement data may immediately be
stored and/or printed
   Leaded devices held in linear transports    Surface mount devices held in component
tray or customer specified pallet array
 SPECIFICATIONS  Frequency Range:  10 MHz - 300 MHz  Plating Performance:  ± 4  ppm  typical final frequency    The component area is customized to
precise device size requirements
   Proprietary  measurement technique    Does not require a variable inductor    Precise X-Y table positioning