• System Software • Closed Loop Water Cooled
Filament • Bar Code Reader (Optional) • Printer (Optional) • Quartz Crystal Plating (Optional) 6300108-09 MEASUREMENTS • Resonator 1 • Resistance • Inductance • Capacitance • Resonator 2 • Resistance • Inductance • Capacitance • Center Frequency • Symmetry • Short Circuit Bandwidth • Resonator Frequency Port 1 • Resonator Frequency Port 2 • Total Resistance SYSTEM CONFIGURATION • Vector Voltmeter • Dual Output Synthesizers • X-Y Table Vacuum Assembly • Turbo or Cryo Pump • Direct Drive Roughing Pump • Computer • Light Pole SAUNDERS & ASSOCIATES, INC. FACILITY REQUIREMENTS • Power: 220 Volts @ 30 A or 380 Volts @ 20 A, 3-Phase • Inlet Pressures: 150 PSIG Maximum • Air: 90 PSIG • Nitrogen: 20 PSIG (Turbo), 70 PSIG (cryo) • Cryo Water Cooling: 0.5 GPM @70 ° F, typical • Dimensions: 52.5 x 34.5 x 55 Inches (excluding light pole & cryo compressor) (133.4 x 87.6 x 139.7cm)
Cryo pump compressor 19.5 x 24 x 19 inches
(49.2 x 61 x 48.3 cm) Light pole 39.5 inches (100.3 cm)
S&A 5500B MCF
PLATING SYSTEM • Monolithic Crystal Filter final
frequency adjust plating system • Plates FE1, FE2 and bandwidth to
user specified targets • Measured parameters are checked against easy to define Q.C. limits after
each filter is plated • Measurement data may immediately be
stored and/or printed • Leaded devices held in linear transports • Surface mount devices held in component
tray or customer specified pallet array SPECIFICATIONS Frequency Range: 10 MHz - 300 MHz Plating Performance: ± 4 ppm typical final frequency • The component area is customized to
precise device size requirements • Proprietary measurement technique • Does not require a variable inductor • Precise X-Y table positioning